Sekumatic™ FDR
The aldehyde-free and efficient liquid for the chemo-thermal reprocessing in bed and cart decontamination systems. With unique active agent Glucoprotamin®. Suitable also for the chemo-thermal bedpan disinfection as well as for disinfection of respirator protection masks in washer-extractors and RDGs.
Product Details
The aldehyde-free and efficient liquid for the chemo-thermal reprocessing in bed and cart decontamination systems.
- Secure disinfection
- Effective cleaning
- Good material compatibility
Our performance | Your advantage |
---|---|
Aldehyde-free with unique active agent Glucoprotamin |
Secure disinfection at 60°C, user-friendly formulation without aldehyde |
Low in surfactants, pH-neutral | Particularly low in foam, very good material compatibility, high cleaning performance |
Optimally matched formulation components |
Meets the requirements of “AK-BWA” |
Certified by DEDEKRA EXAM (Testing institute for Respirator Protection) | Safe and material-friendly disinfection of respiratory protective devices |
High safety of use by automated dosing | Precise dosing. No product contact by the user |
When used in cleaning and disinfection devices (RDG) in the medical area, we recommend using a concentration of 10ml/l at 60°C and a contact time of at least 5 minutes. Observe the system manufacturer's instructions.
Recommended concentrations for use in bed and container washers are 5-10ml/l at 60°C and 90-120 seconds contact time.
When using in washer-extractors and RDGs for cleaning and disinfection of respirator protection masks, it is recommended that dosing of Sekumatic FDR be done above a temperature of 60°C. Observe the system manufacturer's instructions.
Composition
Nicotinic surfactants, alcoholic solvents, sequestrants, corrosion inhibitors
100g contains as agents:
2.0 g glucoprotamine, 2.0 g poly(oxy-1, 2-ethandiyl), alpha-[2-(didecylmethyl-ammonio) ethyl]-omega-hydroxy-, propanoate (salt), 0.75 g benzalconium chloride
Use (after commencement) | Shelf life |
---|---|
|
|
1
Please note the following to ensure the correct storage of environmental hygiene and instrument disinfectants: The original containers (canisters, buckets or bottles) with the disinfectant concentrate (or powder) should be stored at temperatures below 25°C and kept dry and clean. A brief period below or above the given storage temperature (e.g. during transport) will not diminish the effectiveness.
The containers are to be sealed tightly after each use. Please also take care that the concentrate remaining in the container is not contaminated when preparing the application solution.
Chemical- physical data | ||
---|---|---|
Density | 20 °C | 1.03 g / ml |
pH value* (concentrate) | 20 °C | ca. 5.5 |
pH-value* (liquid, 5-10ml/l in DM-water) | 20 °C | 6 – 8 |
* pH-value measurements under operating conditions always by using pH-meter with temperature compensation.
Disinfectant for medical devices
0297
Use biocide products with caution. Always read the label and product information before use.